Fire Doors

Other Passive Fire Equipment

Passive fire protection is an integral component of structural fire protection and fire safety in a building. Passive Fire Protection attempts to contain fires or slow the spread, through use of fire-resistant walls, floors, and doors.

Passive fire protection includes compartmentalisation of the overall building through the use of fire-resistance rated walls and floors. Organization into smaller fire compartments, consisting of one or more rooms or floors, prevents or slows the spread of fire from the room of fire origin to other building spaces, limiting building damage and providing more time to the building occupants for emergency evacuation or to reach an area of refuge.

The aim for passive fire protection systems is typically demonstrated in fire testing the ability to maintain the item or the side to be protected at or below either 140 °C (for walls, floors and electrical circuits required to have a fire-resistance rating) or ca. 550 °C, which is considered the critical temperature for structural steel, above which it is in jeopardy of losing its strength, leading to collapse. 

To accomplish these aims, many different types of materials are employed in the design and construction of systems. For instance, common endothermic building materials include concrete and gypsum wallboard. During fire testing of concrete floor slabs, water can be seen to boil out of a slab. Gypsum wall board typically loses all its strength during a fire. The use of endothermic materials is established and proven to be sound engineering practice. The chemically bound water inside these materials sublimes. During this process, the unexposed side cannot exceed the boiling point of water. Once the hydrates are spent, the temperature on the unexposed side of an endothermic fire barrier tends to rise rapidly. Too much water can be a problem, however. Concrete slabs that are too wet, will literally explode in a fire, which is why test laboratories insist on measuring water content of concrete and mortar in fire test specimens, before running any fire tests.

Passive Fire Protection measures are intended to contain a fire in the fire compartment of origin, thus limiting the spread of fire and smoke for a limited period of time, as determined the local building code and fire code. Passive fire protection measures, such as firestops, fire walls, and fire doors, are tested to determine the fire resistance rating of the final assembly, usually expressed in terms of hours of fire resistance.

Contrary to active fire protection measures, passive fire protection means do not typically require electric or electronic activation or a degree of motion. Exceptions to that particular rule of thumb are fire dampers (fire-resistive closures within air ducts, excluding grease ducts) and fire door closers, which must move, open and shut in order to work, as well as all intumescent products, which swell, thus move, in order to function.