Understanding AS 1851 Clause 1.5.20: Testing Requirements for Non-Automatic Fire Protection Equipment
AS 1851 is the Australian Standard that defines maintenance and inspection requirements for fire protection systems and equipment. Clause 1.5.20 specifically addresses the testing requirements for non-automatic fire protection equipment, which includes devices that rely on human intervention to activate or signal an emergency. For facility managers, building owners, and fire safety professionals, understanding these testing requirements is essential for maintaining AS 1851 compliance and ensuring equipment performs when needed.
What Is Non-Automatic Fire Protection Equipment?
Non-automatic fire protection equipment refers to devices and systems that do not activate independently but require a person to initiate their function. Common examples covered under AS 1851 Clause 1.5.20 include:
- Manual call points (break-glass or push-button devices)
- Fire alarm sounders and horns
- Fire alarm control panel annunciators
- Emergency voice communication systems (manual activation components)
These items differ from automatic systems such as fire sprinklers or gas suppression systems, which trigger without human input. Despite their simplicity, non-automatic equipment plays a critical role in early fire detection and alerting occupants to evacuate.
Testing Requirements Under AS 1851 Clause 1.5.20
AS 1851 specifies a tiered approach to inspection and testing for non-automatic fire protection equipment. The standard defines three primary levels of assessment:
1. Visual Inspection
Conducted at regular intervals (typically monthly), this checks for physical damage, obstruction, correct signage, accessibility, and general condition. The inspector verifies that manual call points are unbroken, sounders are unobstructed, and control panel indicators are functioning.
2. Functional Test
Performed at set intervals (typically annually), this test verifies that the equipment operates as intended. For manual call points, this involves activating the device and confirming the control panel registers the alarm. For sounders, the test confirms audible output at the required level.
3. Detailed Inspection
A more thorough examination that may include checking electrical connections, component integrity, and compliance with the original installation design.
Each inspection and test must be documented. AS 1851 requires that records include the date, nature of the work performed, results, and the identity of the person carrying out the task. These records form part of the compliance file for the building.
Common Failure Points in Non-Automatic Equipment
Non-automatic fire protection equipment is subject to several predictable failure modes. Identifying these during routine testing prevents equipment from failing during an actual emergency.
- Physical damage: Manual call points suffer from accidental breakage, vandalism, or impact damage in high-traffic areas such as car parks and loading docks.
- Obstruction: Sounders and horns become covered by dust, storage items, or building modifications, reducing or eliminating their audible output.
- Electrical faults: Battery failure in control panels, corroded terminals, or wiring issues can prevent alarm signals from being transmitted or sounded.
- Signage and accessibility: Equipment becomes hidden behind signage, shelving, or decorative features, making it difficult for occupants to locate during an emergency.
- Environmental factors: In industrial or coastal environments, moisture, corrosion, and extreme temperatures accelerate component degradation.
Compliance Obligations for Facility Managers
In Australia, fire safety compliance is governed by a combination of state and territory legislation, local council requirements, and insurance policies. AS 1851 serves as the benchmark for how fire protection equipment should be maintained, and most regulatory frameworks reference it directly or indirectly.
Facility managers and building owners carry the responsibility for ensuring that all fire protection equipment, including non-automatic systems, is inspected and tested at the intervals specified by AS 1851. Failure to maintain compliant records can result in:
- Non-compliance notices from local council or the relevant fire authority
- Increased insurance premiums or policy non-renewal
- Liability exposure in the event of a fire where equipment failure contributed to harm
Engaging a qualified fire protection contractor to perform scheduled inspections provides a documented chain of accountability and reduces the risk of oversight.
Practical Considerations for Commercial and Industrial Facilities
When planning maintenance programs for non-automatic fire protection equipment, facility teams should consider the following:
- Asset register accuracy: Maintain a current register of all manual call points, sounders, and control panels, including location, type, and installation date. Changes to tenancy or fit-out work should trigger an update.
- Access planning: Schedule functional tests during periods of low occupancy where possible. In 24/7 operational facilities, coordinate with site teams to minimise disruption.
- Replacement thresholds: AS 1851 does not specify a fixed service life for non-automatic equipment, but components that show signs of end-of-life (fading legends, brittle casings, intermittent faults) should be replaced rather than repeatedly repaired.
- Integration with other systems: Non-automatic equipment often feeds into a broader fire detection and alarm system. Testing one component in isolation may not reveal integration faults. Annual functional tests should verify the full signal path from call point to control panel to sounders.
Frequently Asked Questions
How often must non-automatic fire protection equipment be tested under AS 1851?
AS 1851 Clause 1.5.20 requires visual inspections at regular intervals, typically monthly, and functional tests at least annually. The exact frequency may be adjusted by the system designer or local authority, but the standard intervals form the minimum baseline for compliance.
What happens if a manual call point is broken or damaged?
A damaged manual call point must be repaired or replaced as soon as practicable. The defect should be recorded in the maintenance log, and if the equipment cannot be made operational immediately, a temporary measure such as a signage notice or increased patrol frequency should be implemented until the fix is completed.
Who is qualified to perform AS 1851 testing on non-automatic fire protection equipment?
Testing should be carried out by a person with appropriate knowledge and experience in fire protection systems. In practice, this is a licensed fire protection contractor or a trained in-house fire safety officer. The standard requires the person to be competent and for records to identify who performed the work.
Does AS 1851 apply to all building types in Australia?
AS 1851 is the nationally recognised standard for fire protection equipment maintenance and is referenced by most state and territory fire safety regulations. It applies to commercial, industrial, residential (multi-dwelling), and institutional buildings.
Can I combine AS 1851 testing with other maintenance activities?
Yes. Many facility teams schedule fire protection equipment inspections alongside general building maintenance to reduce access disruptions. However, the fire protection work must still be performed to the AS 1851 specification and documented separately in the fire safety compliance file.
Conclusion
Non-automatic fire protection equipment is simple in design but critical in function. The testing requirements under AS 1851 Clause 1.5.20 exist to ensure that when a person needs to raise the alarm, the system responds reliably. A structured inspection program, accurate record-keeping, and prompt remediation of defects are the core elements of maintaining compliance and protecting occupants.
If you need a scheduled inspection program for your fire protection equipment or are reviewing your current compliance position, Majestic Fire Protection provides AS 1851-compliant inspection and testing services for commercial and industrial facilities across Australia. Contact the team to arrange an assessment.